Split plummer block housing, 50 mm shaft, two-bolt base
- Shaft diameter50 mm
- BaseTwo-bolt
- MaterialCast iron
- SealLabyrinth
A bearing only works as well as the housing that locates it. A split plummer block lets you fit a self-aligning bearing onto a long shaft without dismantling the whole drive, and it gives you a bolted base, a seal at each end and a grease point you can reach in service. A mounted unit goes further: the bearing insert and the housing arrive as one pre-greased, sealed assembly that bolts straight onto a welded frame. Both exist because most industrial frames are welded, not line-bored, and because maintenance crews need to change a bearing without pulling the shaft. The two differ in what you buy — a housing plus a separate bearing and sleeve, or a complete unit — and we quote both forms as one line item with the same lot number on the inspection record.
Neither form is chosen by the bearing bore alone. The shaft diameter, the bolt-hole layout, the direction of the load relative to the base and the environment decide the housing, the seal and the material.
A split bearing housing is a two-piece cast base and cap bored to accept a self-aligning ball or spherical roller bearing, usually mounted on the shaft with an adapter sleeve. Because the cap lifts off, the bearing can be fitted, inspected or replaced without sliding it along the shaft — the reason these housings dominate long conveyor drives, fan and blower shafts, crusher and quarry equipment, paper mill rollers, water treatment plants and any shaft that is easier to leave in place. The housing carries the bolt-down base, provides a grease point, and accepts a seal at each end; the spherical bore of the bearing inside it forgives the small alignment errors that come from a welded or separately cast frame. Standard bases are two-bolt or four-bolt, and the material is normally grey cast iron, ductile iron, cast steel or stainless for washdown and corrosive areas.
Specify the shaft diameter and the bearing designation first, because those two set the housing size. Then give the base type and the bolt-hole spacing and bolt size, the height from the base to the shaft centre, and the direction and magnitude of the load relative to the base — a load pulling upward on the cap asks for a different housing than one pressing down into the base. Choose the seal: a labyrinth or felt seal for dusty dry conditions, a lip seal for wet or washdown areas, and an end cover if the shaft terminates at the housing. Tell us whether this position is the locating bearing or the free (floating) end of the shaft, since the free end needs a bearing that can move axially in its seat. State the lubrication method, the operating temperature and the environment, and include the flatness and finish of the mounting pad if the frame is already machined. We supply the housing, bearing, sleeve and seals as a matched set from the partner factory with the bore and bolt layout on the inspection record, and we will confirm the shaft-centre height before the order is placed.
A mounted unit is a sealed, pre-greased insert bearing already fitted into a bolt-on housing. The insert has a spherical outside surface that sits in a matching spherical bore in the housing, so it can pivot and align with the shaft while the housing stays bolted to the frame. That single property is why mounted units are the default choice on welded frames, agricultural implements, conveyor rollers and idlers, packaging and filling machines, fans, and material handling equipment where line-boring the frame is not practical. The unit is replaced as a whole rather than reconditioned, which keeps downtime short; the common housing forms are pillow block (two-bolt base), flange (two-, three- or four-bolt face mount), take-up (sliding for belt tensioning) and cartridge (round, pressed into a machined bore).
Give the shaft diameter first, then the housing form and the bolt-hole spacing or flange bolt circle. Choose the locking method on the wide inner ring — set screws, an eccentric collar or an adapter sleeve — and tell us the direction of shaft rotation and the vibration level, since those decide which locking method will stay tight. State the housing material: cast iron for general duty, stainless or thermoplastic for food, washdown and corrosive areas, and say whether you need a grease hole, a re-lubricatable insert or a sealed-for-life one. Add the environment (washdown, dust, abrasive grit), the radial and any axial load, the speed and the operating temperature. If you need an end cover, a specific seal arrangement or a closed cap, put it in the RFQ. We can quote the insert alone, the housing alone, or the matched assembly as one line item; for the assembly, the insert and housing carry the same lot number on the packing list so the spherical bore and the insert are a matched pair.
Shaft diameter, bolt-hole layout, load direction and environment. Add the bearing designation or the locking method, and say whether the position is locating or free. If you only have a photo of the failed unit, measure the shaft, the bolt spacing and the shaft-centre height and send those with the photo — we will identify the form from the dimensions.
Send the dimensions, the quantity and the destination port in one RFQ. We reply with price, MOQ, lead time and Incoterms.