6205-2RS deep groove ball bearing, 25 × 52 × 15 mm
- Bore (d)25 mm
- Outside diameter (D)52 mm
- Width (B)15 mm
- Seal2RS rubber contact seals
- ClearanceC0
A deep groove ball bearing has uninterrupted raceway grooves whose depth is close to a quarter of the ball diameter. That geometry lets it carry radial load and a useful amount of axial load in both directions, with low friction and a high speed ceiling — the reason it is the most widely fitted bearing in industry and the first part number most buyers send us. It is not one product, though. The seal, the internal clearance, the precision grade and the cage change what the same 25 × 52 × 15 mm envelope can do: a sealed C3 version on a hot motor shaft and an open P5 version in a machine tool spindle are different purchases even though a caliper reads the same three numbers on both. We stock the common metric sizes and source the rest through audited partner factories, so a mixed part list across seal types and clearances can travel as one consignment with one inspection record.
| Variant | What changes | Choose it when |
|---|---|---|
| Open type | No seal or shield; lowest friction, highest speed | Lubrication is supplied by the machine (oil bath, oil mist) and the housing is clean |
| ZZ steel shields | Non-contact metal shields; keep coarse dirt out with almost no drag | Moderate contamination, higher speed, grease retained in the bearing |
| 2RS rubber contact seals | Contact seals on both sides; best exclusion of dust and moisture | Washdown, dust, outdoor or agricultural duty; speed ceiling is lower than ZZ |
| 2RZ low-friction seals | Non-contact rubber seals | You need better exclusion than ZZ without the drag of a contact seal |
| C3 internal clearance | Greater radial clearance than C0 | Tight fits, hot housings, or a long shaft that grows with temperature |
| Stainless or flanged | Ring material, or a flange on the outer ring for axial location | Food, marine and medical equipment, or a housing with no shoulder |
| P5 / P4 precision | Tighter runout and dimensional tolerance | Spindles, servo motors and precision axes |
Start with bore (d), outside diameter (D) and width (B) — or the designation printed on the old part, such as 6205-2RS. Then give the seal type, the internal clearance, the precision grade and the cage material if your drawing calls them out. Add the radial and axial loads, the speed, the operating temperature and the lubrication method, because a 2RS seal and a C0 clearance that are fine on a cool conveyor roller will run hot on a motor. State the shaft and housing fit tolerances: an interference fit on the inner ring consumes part of the internal clearance, which is why C3 is common on press-fitted motor bearings. Finally, give the quantity per part number, the packaging requirement and the Incoterm. If you only have a photo of the marking, send it with a caliper measurement and we will confirm the three dimensions before quoting.
Electric motors and generators, centrifugal pumps and fans, gearboxes and reducers, conveyor rollers and idlers, agricultural machinery, household and commercial appliances, power tools, automotive auxiliaries, printing and packaging machines, and general MRO replacement. In each case the failure mode points to the variant: grease loss and dust call for 2RS, overheating on a press fit calls for C3, and a spindle that has to run true calls for a higher precision grade.
Most replacement enquiries start with a bearing that failed in service, not with a new design. Measure the bore, outside diameter and width, read the seal and any suffix off the old ring, and note the direction of the axial load and the running temperature. We match those values to the standard designation in our catalog and confirm the three fit dimensions in the first reply; we do not assume that a suffix from one numbering system means the same thing in another. If the old bearing failed early, tell us how: rust or washed-out grease points to the seal, blueing or hot grease to the clearance or the fit, and a brinelled raceway to shock or a bad installation. That answer changes the variant we quote. We do not list third-party brand names as our own products, and we state interchangeability only as a match of dimensions and construction, never as a claim of brand authorization.
Use 2RS contact seals where dust, water or washdown will reach the bearing. Use ZZ steel shields where the housing is reasonably clean and speed matters, because shields add almost no drag. Choose an open type only when the machine supplies its own clean lubrication; an open bearing in an unsealed dirty housing will not last.
When the inner ring is press-fitted, the housing runs hot, or the shaft is long enough to grow visibly with temperature. An interference fit uses up part of the internal clearance, so a C0 bearing can end up preloaded and run hot. If none of those apply, C0 is the normal choice — C3 is not an upgrade in every installation.
Yes. Mixed part lists are normal for us and each line keeps its own MOQ. Put one part number per line with its quantity, and we reply with unit price, MOQ, lead time, packing and Incoterms for the whole list in one message.
Send the bore, outside diameter, width and the duty in one RFQ. We confirm the fit before quoting and state MOQ, lead time and Incoterms.